  "schemaVersion": 1,
  "reference": "CANDU 6, May 2005 baseline; not EC6",
  "retrieved": "2026-11-06",
  "units": "Metres, Y up, channel axis Z. mm × 0.001 = m. Temperatures °C; pressure basis explicit. No solver.",
  "sources": [
    {
      "id": "aecl-2005",
      "title": "CANDU 6 Technical Summary",
      "author": "AECL, CANDU 6 Program Team, Reactor Development Business Unit",
      "revision": "May 2005",
      "url": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf",
      "sha256": "9a3be4fc903d5badeea45421028ce26d80cde475fffea0a2daa7c3d9190367ed",
      "bytes": 3750236,
      "readDepth": "Printed pp.4,8–9,12–15,28–29; cover; visuals pp.9,13,15. PDF p = printed p + 3 (one-based).",
      "rights": "Third-party publication; linked, not redistributed. Authored geometry is independent."
    },
    {
      "id": "cnsc-pressure-tubes",
      "title": "Pressure tubes: The heart of the reactor",
      "author": "Canadian Nuclear Safety Commission",
      "url": "https://www.cnsc-ccsn.gc.ca/eng/resources/fact-sheets/pressure-tubes.cfm",
      "locator": "Inside the reactor",
      "readDepth": "Component-role paragraphs; operational fitness discussion not used for predictions.",
      "rights": "Linked only"
    },
    {
      "id": "nbpower-profile",
      "title": "Nuclear / Station Profile",
      "author": "NB Power",
      "url": "https://www.nbpower.com/en/about-us/our-business/nuclear",
      "locator": "Station Profile",
      "readDepth": "380 channels, 4560 bundles, 37 elements, 4 pumps and 4 boilers; output labels compared only.",
      "rights": "Linked only"
    },
    {
      "id": "aecl-doria-2001",
      "title": "CANDU Safety #4: Thermalhydraulic Safety Characteristics of CANDU Reactors",
      "author": "F. J. Doria, Atomic Energy of Canada Limited",
      "revision": "Rev. 0, 24-May-2001",
      "url": "https://canteach.candu.org/Content%20Library/19990104.pdf",
      "sha256": "46d27be5edcc1543f1ad88510e7522bf24885311f13861ffc7f66554e3e3baf2",
      "bytes": 1183430,
      "retrieved": "2026-11-07",
      "readDepth": "Slides 1, 3–4 and 22; slide 22 visually inspected. Supporting channel dimensions and circuit topology only; no safety-performance claims imported.",
      "rights": "Third-party slides linked only; no images redistributed."
    }
  ],
  "parameters": {
    "channels": {
      "value": 380,
      "unit": "count",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": ""
    },
    "bundlesPerChannel": {
      "value": 12,
      "unit": "count",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": ""
    },
    "elementsPerBundle": {
      "value": 37,
      "unit": "count",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": ""
    },
    "coreLength": {
      "value": 5.94,
      "unit": "m",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": "Between calandria tubesheets; not total pressure-tube/end-fitting length."
    },
    "pressureTubeInsideDiameter": {
      "value": 0.10338,
      "unit": "m",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": "103.38 mm, cold and unpressurized."
    },
    "bundleLength": {
      "value": 0.4953,
      "unit": "m",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": "495.3 mm; the nominal bundle envelope includes end hardware."
    },
    "bundleDiameter": {
      "value": 0.1024,
      "unit": "m",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": "102.4 mm over bearing pads, not the bare fuel-rod circle."
    },
    "sheathDiameter": {
      "value": 0.0131,
      "unit": "m",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": "13.1 mm cold outside diameter."
    },
    "sheathThickness": {
      "value": 0.0004,
      "unit": "m",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": "0.4 mm average; pellet dimensions are not inferred from this."
    },
    "htsLoops": {
      "value": 2,
      "unit": "count",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "pp.14,28",
      "note": ""
    },
    "steamGenerators": {
      "value": 4,
      "unit": "count",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.29",
      "note": ""
    },
    "primaryPumps": {
      "value": 4,
      "unit": "count",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.29",
      "note": ""
    },
    "channelSpacers": {
      "value": 4,
      "unit": "count",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.8",
      "note": ""
    },
    "moderatorPumps": {
      "value": 2,
      "unit": "count",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "pp.12–13",
      "note": ""
    },
    "moderatorExchangers": {
      "value": 2,
      "unit": "count",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "pp.12–13",
      "note": ""
    },
    "moderatorInletTemperature": {
      "value": 70,
      "unit": "degC",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.13",
      "note": "Approximately; a source annotation, never a computed field."
    },
    "htsInletTemperature": {
      "value": 266,
      "unit": "degC",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": ""
    },
    "htsOutletTemperature": {
      "value": 310,
      "unit": "degC",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": ""
    },
    "htsOutletPressure": {
      "value": 10,
      "unit": "MPa(abs)",
      "evidence": "documented",
      "source": "aecl-2005",
      "locator": "p.28",
      "note": ""
    },
    "calandriaRadius": {
      "value": 3.8,
      "unit": "m",
      "evidence": "illustrative",
      "source": null,
      "locator": "A01",
      "note": "Envelope radius chosen to contain the illustrative channel lattice; not recovered from a dimensioned drawing."
    },
    "calandriaWall": {
      "value": 0.08,
      "unit": "m",
      "evidence": "illustrative",
      "source": null,
      "locator": "A01",
      "note": "Display envelope thickness."
    },
    "latticePitch": {
      "value": 0.286,
      "unit": "m",
      "evidence": "illustrative",
      "source": null,
      "locator": "A02",
      "note": "Square lattice is documented on p.8; pitch and occupied positions here are assumed."
    },
    "pressureTubeWall": {
      "value": 0.0042,
      "unit": "m",
      "evidence": "documented",
      "source": "aecl-doria-2001",
      "locator": "slide 22",
      "note": "Supporting 2001 source, not a manufacturing specification. 4.2 mm nominal wall."
    },
    "calandriaTubeInsideRadius": {
      "value": 0.0645,
      "unit": "m",
      "evidence": "derived",
      "source": "aecl-doria-2001",
      "locator": "slide 22",
      "note": "Supporting 2001 source, not a manufacturing specification. 129 mm nominal inside diameter / 2."
    },
    "calandriaTubeOutsideRadius": {
      "value": 0.0659,
      "unit": "m",
      "evidence": "derived",
      "source": "aecl-doria-2001",
      "locator": "slide 22",
      "note": "129 mm / 2 + 1.4 mm nominal wall. Replaces the original 67 mm illustrative outer radius; no tolerance or operating deformation implied."
    },
    "pressureTubeLength": {
      "value": 6.1,
      "unit": "m",
      "evidence": "illustrative",
      "source": null,
      "locator": "A03",
      "note": "Allows end extension around the 5.94 m tubesheet span; complete assembly length is unknown."
    },
    "calandriaTubeWall": {
      "value": 0.0014,
      "unit": "m",
      "evidence": "documented",
      "source": "aecl-doria-2001",
      "locator": "slide 22",
      "note": "Nominal 2001 supporting-source wall, not qualified manufactured thickness."
    }
  },
  "components": [
    {
      "id": "CANDU-CAL",
      "name": "Calandria and end shields",
      "shortName": "Calandria and end shields",
      "parent": null,
      "system": "Moderator",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "Horizontal low-pressure moderator tank surrounding the channels. The moderator stays outside the calandria tubes. End shields and tank dimensions are illustrative envelopes; the site buildings are not a station layout.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=11",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.8",
      "properties": [
        [
          "Channel count",
          "380; illustrative square-lattice occupancy",
          "documented"
        ],
        [
          "Tubesheet span",
          "5.94 m (p.28); not full channel length",
          "documented"
        ],
        [
          "Calandria radius / wall",
          "3.8 m / 0.08 m, assumed",
          "illustrative"
        ],
        [
          "Not shown",
          "Reactivity devices, vault water, detailed shielding and containment",
          "unknown"
        ]
      ]
    },
    {
      "id": "CANDU-CHANNELS",
      "name": "Fuel-channel array",
      "shortName": "Fuel-channel array",
      "parent": null,
      "system": "Heat transport",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "380 channel locations including the central representative channel. The square-lattice principle is sourced; pitch and occupancy are illustrative. Cutaway removes a reader-facing sector to expose the assembly, so fewer envelopes are visible.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=11",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.8",
      "properties": [
        [
          "Channels",
          "380 (p.28)",
          "documented"
        ],
        [
          "Pitch",
          "0.286 m, assumed",
          "illustrative"
        ],
        [
          "Loading map",
          "Not modelled",
          "unknown"
        ]
      ]
    },
    {
      "id": "CANDU-PT",
      "name": "Pressure tube",
      "shortName": "Pressure tube",
      "parent": null,
      "system": "Heat transport",
      "evidence": "reconstructed",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "Contains fuel bundles and hot pressurized primary heavy water. The cooler moderator is outside the separate calandria tube. This geometric inspection does not assess fitness for service.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=31",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.28",
      "properties": [
        [
          "Inside diameter",
          "103.38 mm, cold/unpressurized (p.28)",
          "documented"
        ],
        [
          "Wall / displayed length",
          "4.2 mm nominal wall (2001 slide 22) / 6.1 m assumed length",
          "mixed"
        ],
        [
          "Source materials",
          "Zirconium-niobium alloy pressure tube (p.8)",
          "documented"
        ]
      ]
    },
    {
      "id": "CANDU-CT",
      "name": "Calandria tube",
      "shortName": "Calandria tube",
      "parent": null,
      "system": "Moderator",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "Separates the low-pressure moderator from the insulating gas annulus around the pressure tube. Its section is shown independently from the pressure boundary.",
      "source": "https://canteach.candu.org/Content%20Library/19990104.pdf#page=22",
      "sourceLabel": "AECL · F. J. Doria, Rev. 0 (2001), slide 22",
      "properties": [
        [
          "Inside diameter / wall",
          "129 mm / 1.4 mm nominal (2001 slide 22)",
          "documented"
        ],
        [
          "Outside diameter",
          "131.8 mm = 129 + 2 × 1.4 mm",
          "derived"
        ],
        [
          "Shown length",
          "6.1 m envelope; complete axial interfaces unresolved",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-GAS",
      "name": "Insulating gas annulus",
      "shortName": "Insulating gas annulus",
      "parent": null,
      "system": "Channel insulation",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "The CO₂-filled annulus thermally separates the hot pressure tube from the cooler calandria tube. The translucent tint is a display cue, not a fluid calculation.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=11",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.8",
      "properties": [
        [
          "Fluid",
          "CO₂ (p.8)",
          "documented"
        ],
        [
          "Gap size",
          "Derived from assumed tube walls/radii",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-FUEL",
      "name": "Representative fuel bundles",
      "shortName": "Representative fuel bundles",
      "parent": null,
      "system": "Fuel",
      "evidence": "reconstructed",
      "detail": "Published anchors; illustrative geometry",
      "material": "Zircaloy sheath display; natural UO₂ fuel not individually modelled",
      "description": "The full-channel detail shows 12 bundles of 37 elements. Bundle detail shows one bundle at the same scale. Rod centres, bearing pads and end-plate pattern are illustrative; pellets and detailed welds are omitted. Sheaths and end caps are represented; pellets are omitted. Ring radii, phases and hardware profiles are assumptions.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=31",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.28",
      "properties": [
        [
          "Bundles per channel",
          "12",
          "documented"
        ],
        [
          "Elements per bundle",
          "37",
          "documented"
        ],
        [
          "Bundle envelope",
          "495.3 mm long; 102.4 mm over bearing pads",
          "documented"
        ],
        [
          "Element sheath",
          "13.1 mm OD cold; average wall 0.4 mm",
          "documented"
        ],
        [
          "Fuel",
          "Natural uranium dioxide",
          "documented"
        ],
        [
          "Train/span discrepancy",
          "12 × 495.3 mm = 5.9436 m; tubesheet span is 5.94 m. Both retained.",
          "documented"
        ]
      ]
    },
    {
      "id": "CANDU-SPACERS",
      "name": "Annulus spacers",
      "shortName": "Annulus spacers",
      "parent": null,
      "system": "Channel insulation",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "Four schematic spacers maintain separation between the pressure tube and calandria tube. Locations and wire profile are assumed; their presence is not proof of contact clearance.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=11",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.8",
      "properties": [
        [
          "Count",
          "4 (p.8)",
          "documented"
        ],
        [
          "Spacing and cross-section",
          "Illustrative",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-ENDS",
      "name": "End fittings and feeder connections",
      "shortName": "End fittings and feeder connections",
      "parent": null,
      "system": "Heat transport",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "End fittings connect the channel to feeders and provide access for fuelling. Shield/closure plugs are represented by envelopes. The cutaway is not a maintenance sequence.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=12",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.9",
      "properties": [
        [
          "Functions",
          "Feeder connection and channel access",
          "documented"
        ],
        [
          "Fittings, plugs and dimensions",
          "Illustrative; detailed seals omitted",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-HTS1",
      "name": "Heat-transport loop 1",
      "shortName": "Heat-transport loop 1",
      "parent": null,
      "system": "Heat transport",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "One of two separate figure-of-eight circuits: outlet header → steam generator primary tubes → pump → inlet header → channels → opposite-end outlet → second steam generator and pump → return channels. Each loop serves half the core with opposite flow through adjacent channels; only representative feeders are drawn.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=17",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.14",
      "properties": [
        [
          "Loops",
          "2; each serves half the 380 channels",
          "documented"
        ],
        [
          "Primary fluid",
          "Pressurized D₂O",
          "documented"
        ],
        [
          "Reactor inlet / outlet",
          "266 / 310 °C (p.28), source values only",
          "documented"
        ],
        [
          "Outlet pressure",
          "10.0 MPa absolute (p.28)",
          "documented"
        ],
        [
          "Routing and feeder count shown",
          "Illustrative subset; not an engineering P&ID",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-HTS2",
      "name": "Heat-transport loop 2",
      "shortName": "Heat-transport loop 2",
      "parent": null,
      "system": "Heat transport",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "One of two separate figure-of-eight circuits: outlet header → steam generator primary tubes → pump → inlet header → channels → opposite-end outlet → second steam generator and pump → return channels. Each loop serves half the core with opposite flow through adjacent channels; only representative feeders are drawn.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=17",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.14",
      "properties": [
        [
          "Loops",
          "2; each serves half the 380 channels",
          "documented"
        ],
        [
          "Primary fluid",
          "Pressurized D₂O",
          "documented"
        ],
        [
          "Reactor inlet / outlet",
          "266 / 310 °C (p.28), source values only",
          "documented"
        ],
        [
          "Outlet pressure",
          "10.0 MPa absolute (p.28)",
          "documented"
        ],
        [
          "Routing and feeder count shown",
          "Illustrative subset; not an engineering P&ID",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-SG",
      "name": "Four steam generators",
      "shortName": "Four steam generators",
      "parent": null,
      "system": "Steam generation",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "Primary heavy water transfers heat through inverted U-tubes to separate secondary light water. Four SGs are shown; shell sizes, tube counts and placement are illustrative.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=17",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.14",
      "properties": [
        [
          "Count",
          "4 (p.29)",
          "documented"
        ],
        [
          "Fluid separation",
          "Heavy water in primary tubes; light water/steam on secondary side",
          "documented"
        ],
        [
          "Display geometry",
          "Illustrative shell and tube envelopes",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-PZR",
      "name": "Pressurizer",
      "shortName": "Pressurizer",
      "parent": null,
      "system": "Heat transport",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "A pressurizer connects to outlet headers at one end. Schematic branches include isolation valve envelopes; no pressure control or loss-of-coolant response is simulated.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=17",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.14",
      "properties": [
        [
          "Connection",
          "Outlet headers; isolation provisions described on p.14",
          "documented"
        ],
        [
          "Sizing and placement",
          "Assumed",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-MOD",
      "name": "Moderator cooling circuit",
      "shortName": "Moderator cooling circuit",
      "parent": null,
      "system": "Moderator",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "A separate low-pressure heavy-water inventory circulates from the calandria through two pumps and two heat exchangers and back. Service-water heat rejection is a distinct secondary circuit. This is not a bypass into the primary coolant.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=16",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.13",
      "properties": [
        [
          "Pumps / heat exchangers",
          "2 / 2 (pp.12–13)",
          "documented"
        ],
        [
          "Calandria inlet",
          "Approximately 70 °C (p.13), source annotation",
          "documented"
        ],
        [
          "Piping",
          "Illustrative common headers; purification/cover-gas omitted",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-SERVICE",
      "name": "Moderator service-water boundary",
      "shortName": "Moderator service-water boundary",
      "parent": null,
      "system": "Service water",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "Separate service-water connections remove heat across the moderator heat exchangers. The external cooling source and sink terminate at the model boundary; no station-specific heat-rejection system is inferred.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=16",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.13",
      "properties": [
        [
          "Interface",
          "Heat exchange only; no mixing with moderator",
          "documented"
        ],
        [
          "Source and sink",
          "Off-model; site-specific",
          "unknown"
        ]
      ]
    },
    {
      "id": "CANDU-SECONDARY",
      "name": "Secondary steam and feedwater",
      "shortName": "Secondary steam and feedwater",
      "parent": null,
      "system": "Power conversion",
      "evidence": "illustrative",
      "detail": "Published anchors; illustrative geometry",
      "material": "Illustrative material finish",
      "description": "Four steam-generator secondary outlets join the shared teaching steam line. Feedwater returns to secondary sides. Neither moderator nor primary coolant flows to the turbine. Shared air-cooled condensers and turbine sizing are not the reference station equipment.",
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=7",
      "sourceLabel": "CANDU 6 Technical Summary (May 2005), p.4",
      "properties": [
        [
          "Fluid",
          "Light water / steam, distinct from both D₂O circuits",
          "documented"
        ],
        [
          "Shared plant",
          "Illustrative, not engineering-compatible equipment",
          "illustrative"
        ]
      ]
    },
    {
      "id": "CANDU-SG-PRIMARY",
      "name": "Steam-generator primary tube paths",
      "shortName": "SG primary tubes",
      "system": "Heat transport",
      "evidence": "illustrative",
      "description": "Representative primary heavy-water tube paths inside the steam generators. Heat crosses tube walls to secondary water; the two inventories do not mix. Only representative tubes are drawn.",
      "properties": [
        [
          "Inventory",
          "Primary D₂O",
          "documented"
        ],
        [
          "Geometry",
          "Representative paths, not a tube-count or area model",
          "illustrative"
        ]
      ],
      "source": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf#page=18",
      "sourceLabel": "CANDU 6 Technical Summary (2005), p.15",
      "parent": "CANDU-SG",
      "detail": "Representative tube paths",
      "material": "Tube material not resolved by this geometry packet"
    }
  ],
  "conflicts": [
    {
      "id": "C01",
      "issue": "Rounded six-metre channel description (p.4) versus 5.94 m tubesheet span (p.28).",
      "decision": "Use 5.94 m for tubesheet span only; total pressure tube / fitting lengths assumed. These are not established as identical datums."
    },
    {
      "id": "C02",
      "issue": "12 × 495.3 mm = 5943.6 mm, 3.6 mm longer than 5.94 m tubesheet span.",
      "decision": "Preserve both published numbers. Centre the 5.9436 m train; do not silently shorten bundles or claim a qualified axial stack."
    },
    {
      "id": "C03",
      "issue": "p.15 historical Point Lepreau gross/net 680/633 MWe versus current NB Power profile gross 715000 kW and introductory 660 MW without the same basis.",
      "decision": "No universal CANDU 6 electric output is assigned. Atlas site values remain their separately sourced data; never use this concept to revise station ratings."
    },
    {
      "id": "C04",
      "issue": "p.28 total PHTS flow 7.7 Mg/s and nominal per-channel 24 kg/s do not multiply to the same total across 380 channels.",
      "decision": "Do not derive a flow or heat balance from these labels; omit quantitative flow from the viewer. No silent reconciliation."
    },
    {
      "id": "C05",
      "issue": "PHWR family includes other CANDU designs and non-CANDU PHWRs; p.15 lists different channel counts for Bruce/Darlington.",
      "decision": "CANDU 6 is family reference only. Explicit caveat at every site; no model-name override for all PHWR units."
    },
    {
      "id": "C06",
      "issue": "AECL 2001 slide 22 rounds pressure-tube ID to 103.4 mm; the May 2005 technical summary specifies 103.38 mm cold/unpressurized.",
      "decision": "Retain 103.38 mm and record the 0.02 mm source difference; do not treat it as a tolerance."
    },
    {
      "id": "C07",
      "issue": "A broader CANDU Overview module (CANTEACH 20044210, p.2A-5) lists 6.35 m pressure-tube and 12.4 m overall lengths alongside CANDU 9 context. Applicability to this 2005 CANDU 6 channel is unconfirmed.",
      "decision": "Do not import those lengths. Keep 6.1 m pressure-tube and 8 m end-fitting envelope lengths assumed; the 5.94 m tubesheet span remains separate."
    }
  ],
  "assumptions": [
    {
      "id": "A01",
      "scope": "Plant / reactor",
      "text": "Shared building frames, turbine, air condensers and grid retain existing geometry. Calandria, shielding and equipment envelopes are illustrative, not as-built. Containment, vault water, fuelling machines, reactivity devices and safety systems are omitted."
    },
    {
      "id": "A02",
      "scope": "Channel array",
      "text": "Choose 379 nearest noncentral square lattice positions plus one central detailed channel. Pitch 0.286 m and occupancy are assumed, not a loading map. Cutaway hides a sector of envelopes."
    },
    {
      "id": "A03",
      "scope": "Representative channel",
      "text": "Pressure-tube wall and calandria-tube bore/wall now follow the separately identified 2001 supporting source. Pressure-tube/end-fitting lengths, end hardware, spacer positions and all tolerances remain unresolved or illustrative."
    },
    {
      "id": "A04",
      "scope": "Paths",
      "text": "Topology follows pp.13–15. Routing, piping radii, representative feeders, header positions, pump shells and SG tube counts are illustrative. No velocities, thermal fields or equipment compatibility claimed."
    },
    {
      "id": "A05",
      "scope": "Display",
      "text": "Warm primary outlets, blue primary returns, green moderator pipes, neutral service-water and gold secondary steam distinguish circuits. These are authored display colors, not results. Cut faces cap only the geometric shell section; cutaway is not an opening in operation."
    },
    {
      "id": "A06",
      "scope": "Channel engineering packet",
      "text": "Nominal arithmetic is not a clearance acceptance criterion. Ring radii/phases, element end lengths, pad/plate profiles, spacer sections/positions and end-fitting envelopes are assumed. CAD solids omit pellets and sealing internals. Room-temperature dimensions do not predict hot, irradiated or sagged geometry."
    }
  ],
  "conceptSources": [
    {
      "url": "https://canteach.candu.org/Content%20Library/CANDU6_TechnicalSummary-s.pdf",
      "publisher": "AECL, CANDU 6 Program Team, Reactor Development Business Unit",
      "title": "CANDU 6 Technical Summary",
      "supports": "Printed pp.4,8–9,12–15,28–29; cover; visuals pp.9,13,15. PDF p = printed p + 3 (one-based).",
      "limits": "CANDU 6 reference evidence only. Source-linked, no third-party CAD or document redistribution; plant layout and unsourced dimensions are illustrative, never station as-built or a safety/performance claim."
    },
    {
      "url": "https://www.cnsc-ccsn.gc.ca/eng/resources/fact-sheets/pressure-tubes.cfm",
      "publisher": "Canadian Nuclear Safety Commission",
      "title": "Pressure tubes: The heart of the reactor",
      "supports": "Component-role paragraphs; operational fitness discussion not used for predictions.",
      "limits": "CANDU 6 reference evidence only. Source-linked, no third-party CAD or document redistribution; plant layout and unsourced dimensions are illustrative, never station as-built or a safety/performance claim."
    },
    {
      "url": "https://www.nbpower.com/en/about-us/our-business/nuclear",
      "publisher": "NB Power",
      "title": "Nuclear / Station Profile",
      "supports": "380 channels, 4560 bundles, 37 elements, 4 pumps and 4 boilers; output labels compared only.",
      "limits": "CANDU 6 reference evidence only. Source-linked, no third-party CAD or document redistribution; plant layout and unsourced dimensions are illustrative, never station as-built or a safety/performance claim."
    },
    {
      "url": "https://canteach.candu.org/Content%20Library/19990104.pdf",
      "title": "CANDU Safety #4 · Rev. 0, 24-May-2001",
      "publisher": "F. J. Doria, AECL",
      "supports": "Slides 3–4 circuit topology and slide 22 supporting channel dimensions.",
      "limits": "Training-source nominal values, not a manufacturing specification; no safety predictions are imported."
    }
  ],
  "channelGeometry": {
    "revision": "channel-2",
    "nativeUnit": "mm",
    "axis": "Z",
    "origin": "Channel midpoint; browser translation Y=5 m is plant placement only. CAD XY section maps directly to browser XY.",
    "temperature": "Cold/unpressurized for the 2005 pressure-tube ID and fuel sheath dimensions; other dimensions have no qualified temperature datum.",
    "rings": [
      {
        "count": 1,
        "radiusMm": 0,
        "phaseDeg": 0
      },
      {
        "count": 6,
        "radiusMm": 14.9,
        "phaseDeg": 0
      },
      {
        "count": 12,
        "radiusMm": 28.8,
        "phaseDeg": 15
      },
      {
        "count": 18,
        "radiusMm": 43.3,
        "phaseDeg": 0
      }
    ],
    "ringEvidence": "Counts documented by AECL 2001 slide 22. Radii and relative phases assumed for non-intersecting teaching geometry.",
    "sheathLengthAllowanceMm": 12,
    "endCapLengthMm": 2,
    "endWebThicknessMm": 4,
    "endWebWidthMm": 3,
    "endWebSpanMm": 98,
    "padAxialLengthMm": 25,
    "padAngularWidthDeg": 4,
    "padInnerRadiusMm": 49.5,
    "spacerPositionsMm": [
      -2250,
      -750,
      750,
      2250
    ],
    "spacerAxialWidthMm": 3,
    "endFittingOuterRadiusMm": 95,
    "endFittingEndMm": 4000,
    "closureCenterMm": 3750,
    "closureThicknessMm": 90,
    "closureRadiusMm": 51.69,
    "note": "End caps, open end webs, pad contours, spacers and end fittings are authored envelopes. The source only anchors their roles and selected counts. Pellets, welds, seals, lattice bearings and spacer spring coils are omitted."
  },
  "systems": [
    {
      "id": "primary",
      "label": "Primary heat transport",
      "inventory": "Pressurized heavy water",
      "components": [
        "CANDU-PT",
        "CANDU-HTS1",
        "CANDU-HTS2",
        "CANDU-PZR",
        "CANDU-SG-PRIMARY"
      ],
      "context": [
        "CANDU-FUEL",
        "CANDU-SG"
      ],
      "steps": [
        "Channel pass A → outlet header A",
        "Steam generator A → pump A",
        "Inlet header B → opposite-direction channel pass",
        "Outlet header B → steam generator B → pump B → inlet header A"
      ],
      "source": "aecl-doria-2001",
      "locator": "slides 3–4",
      "page": 4,
      "note": "One figure-of-eight loop is traced here; the second serves the other half of the channels. Pressurizer branches are shared pressure-control context, not a third loop."
    },
    {
      "id": "moderator",
      "label": "Moderator cooling",
      "inventory": "Separate low-pressure heavy water",
      "components": [
        "CANDU-CAL",
        "CANDU-CT",
        "CANDU-MOD"
      ],
      "context": [
        "CANDU-SERVICE"
      ],
      "steps": [
        "Moderator in calandria outside calandria tubes",
        "Two moderator pumps",
        "Two heat exchangers",
        "Return to calandria; service water carries heat away across exchanger walls"
      ],
      "source": "aecl-2005",
      "locator": "pp.12–13",
      "page": 16,
      "note": "The moderator and primary coolant are distinct inventories, despite both using heavy water. Heat-exchanger walls separate moderator and service water."
    },
    {
      "id": "secondary",
      "label": "Secondary steam and feedwater",
      "inventory": "Light water / steam",
      "components": [
        "CANDU-SG",
        "CANDU-SECONDARY"
      ],
      "context": [
        "CANDU-SG-PRIMARY"
      ],
      "steps": [
        "Steam-generator secondary water receives heat across primary tube walls",
        "Steam to turbine",
        "Condenser rejects heat",
        "Feedwater returns to steam generators"
      ],
      "source": "aecl-2005",
      "locator": "pp.14–15",
      "page": 18,
      "note": "Shared turbine and air condensers are illustrative. The detailed reference circuit ends at the steam/feedwater interface; isolation keeps only CANDU component geometry."
    },
    {
      "id": "channel",
      "label": "Channel boundaries",
      "inventory": "Nested material and fluid regions",
      "components": [
        "CANDU-PT",
        "CANDU-CT",
        "CANDU-GAS",
        "CANDU-FUEL",
        "CANDU-SPACERS",
        "CANDU-ENDS"
      ],
      "context": [],
      "steps": [
        "Fuel elements within primary coolant",
        "Pressure tube",
        "CO₂ annulus and spacer envelopes",
        "Calandria tube separates the annulus from moderator"
      ],
      "source": "aecl-2005",
      "locator": "pp.8–9",
      "page": 12,
      "note": "Gas is an insulating gap, not a connection between the two heavy-water systems. Spacer spring coils, pellets and sealing internals are omitted."
    }
  ],
  "interfaces": [
    {
      "id": "I01",
      "from": "Fuel",
      "to": "Primary D₂O",
      "kind": "heat",
      "barrier": "Fuel sheath",
      "component": "CANDU-FUEL",
      "source": "aecl-2005",
      "locator": "pp.8–9"
    },
    {
      "id": "I02",
      "from": "Primary D₂O",
      "to": "Secondary light water",
      "kind": "heat",
      "barrier": "Steam-generator tube wall",
      "component": "CANDU-SG-PRIMARY",
      "source": "aecl-2005",
      "locator": "pp.14–15"
    },
    {
      "id": "I03",
      "from": "Moderator D₂O",
      "to": "Service water",
      "kind": "heat",
      "barrier": "Moderator heat-exchanger wall",
      "component": "CANDU-MOD",
      "source": "aecl-2005",
      "locator": "pp.12–13"
    },
    {
      "id": "I04",
      "from": "Primary D₂O",
      "to": "CO₂ annulus",
      "kind": "boundary",
      "barrier": "Pressure-tube wall; no material flow",
      "component": "CANDU-PT",
      "source": "aecl-2005",
      "locator": "pp.8–9"
    },
    {
      "id": "I05",
      "from": "CO₂ annulus",
      "to": "Moderator D₂O",
      "kind": "boundary",
      "barrier": "Calandria-tube wall; no material flow",
      "component": "CANDU-CT",
      "source": "aecl-2005",
      "locator": "pp.8–9"
    }
  ]
}