Japan · Boiling water reactor

Hamaoka.

4 BWR units at Hamaoka, beside the boiling water reference plant concept. The 3D model shows how the family works; it is not Hamaoka's actual layout.

Back to the globe at Hamaoka
Close view of the illustrative boiling-water plant concept: one tall reactor vessel rising almost to the crane bridge of its open building frame, with steam and recirculation piping at its base and the turbine casing at the right edge.REFERENCE CONCEPT · NOT A SIMULATION

Reference still · interactive view loads when available

Reference concept · Reference · BWR/4

The boiling water reference plant.

The family’s reference concept, not Hamaoka. The model illustrates a boiling water reactor concept, with the generic layout every design in the plant library shares: the reactor island, a turbine hall, air-cooled condensers and a grid connection. It does not show Hamaoka's buildings, number of units, cooling or equipment.

The concept has external recirculation loops, as on earlier boiling water reactor generations. Advanced boiling water reactors (ABWR) move the recirculation pumps inside the vessel, and their units open the ABWR concept.

Fission boils water directly inside the reactor vessel. Separators and a dryer above the core remove droplets before steam leaves for the turbine, so this cycle has no steam generator.

Fuel
Uranium dioxide
Reaction
Splitting heavy nuclei
Energy transfer
Direct cycle: water boils in the vessel

The vessel envelope and main-steam arrangement follow published descriptions; internals spacing, recirculation loops, pedestal, and plant placement are illustrative.

Concept source: US NRC · Boiling water reactors. Procedural geometry drawn for teaching: source anchors are identified in the component records; other dimensions and placement are illustrative. No physics results are computed.

Spotter’s guide · BWR

Boiling water reactor

Water boils inside the reactor vessel and the steam goes straight to the turbine. One loop, no steam generators.

ABWR · ESBWR · BWRX-300

The whole station · Hamaoka

Hamaoka as one power plant.

Every unit on the site, from the atlas’s unit records: each reactor drives its own generator, which feeds the station’s switchyard and the grid. This is a schematic of how the units connect, not the station’s layout; the atlas records no buildings, cooling, switchyard arrangement or grid voltage.

Hamaoka-1: BWR, shut down, 516 MWe netHamaoka-1BWRG516 MWeShut downHamaoka-2: BWR, shut down, 814 MWe netHamaoka-2BWRG814 MWeShut downHamaoka-3: BWR, suspended, 1,056 MWe netHamaoka-3BWRG1,056 MWeSuspendedHamaoka-4: BWR, suspended, 1,092 MWe netHamaoka-4BWRG1,092 MWeSuspendedHamaoka-5: ABWR, suspended, 1,325 MWe net, 3,926 MWt at design ratingHamaoka-5ABWR3,926 MWtG1,325 MWeSuspendedHamaoka-6: ABWR, planned, 3,926 MWt at design ratingHamaoka-6ABWR3,926 MWtG—PlannedSwitchyardGridHamaoka-1: BWR, shut down, 516 MWe netHamaoka-1BWR · 516 MWe · Shut downGHamaoka-2: BWR, shut down, 814 MWe netHamaoka-2BWR · 814 MWe · Shut downGHamaoka-3: BWR, suspended, 1,056 MWe netHamaoka-3BWR · 1,056 MWe · SuspendedGHamaoka-4: BWR, suspended, 1,092 MWe netHamaoka-4BWR · 1,092 MWe · SuspendedGHamaoka-5: ABWR, suspended, 1,325 MWe net, 3,926 MWt at design ratingHamaoka-5ABWR · 1,325 MWe · SuspendedGHamaoka-6: ABWR, planned, 3,926 MWt at design ratingHamaoka-6ABWR · — · PlannedGGrid
  • Planned · 1
  • Suspended · 3
  • Shut down · 2
  • On this page
Operating
None
Being built or planned
1 unit · 0 MWe net
Suspended
3 units · 3,473 MWe net
Shut down
2 units · 1,330 MWe net
Plant concepts here
BWR reference (4) · ABWR (2)