Iran · Experimental power reactors

Bushehr.

2 experimental units at Bushehr. These one-off designs share no reference plant, so this page shows the site's numbers and why no one 3D concept stands for them.

Back to the globe at Bushehr
Other · no single concept

No one plant stands for these.

The units in this group are one-off designs, and this page will not borrow another family’s plant to stand in for them. The section below says what they are.

No single concept

Why there is no model here.

The experimental units filed here share no design. Lucens, EL-4, Niederaichbach and Bohunice-A1 were heavy-water reactors cooled by carbon dioxide; Gentilly-1, Fugen and Winfrith's SGHWR cooled heavy-water-moderated cores with boiling light water; Hallam was a sodium-cooled graphite reactor and Piqua an organic-cooled one. The planned units here are filed without a design in the source data.

Each plant concept in the library is drawn from published descriptions and stands for one family, so a plant borrowed from another family would teach the wrong thing.

Spotter’s guide · Other

Experimental power reactors

One-off designs that fed the grid: heavy-water gas- and organic-cooled units, steam-generating heavy water, sodium-graphite.

SGHWR · HWGCR · OCR

The whole station · Bushehr

Bushehr as one power plant.

Every unit on the site, from the atlas’s unit records: each reactor drives its own generator, which feeds the station’s switchyard and the grid. This is a schematic of how the units connect, not the station’s layout; the atlas records no buildings, cooling, switchyard arrangement or grid voltage.

Bushehr-1: VVER-1000, operating, 915 MWe net, 3,000 MWt at design ratingBushehr-1VVER-10003,000 MWtG915 MWeBushehr-2: VVER-1000, under construction, 974 MWe net, 3,000 MWt at design ratingBushehr-2VVER-10003,000 MWtG974 MWeBuildingBushehr-3: Other, plannedBushehr-3OtherG—PlannedBushehr-4: Other, plannedBushehr-4OtherG—PlannedSwitchyardGridBushehr-1: VVER-1000, operating, 915 MWe net, 3,000 MWt at design ratingBushehr-1VVER-1000 · 915 MWeGBushehr-2: VVER-1000, under construction, 974 MWe net, 3,000 MWt at design ratingBushehr-2VVER-1000 · 974 MWe · BuildingGBushehr-3: Other, plannedBushehr-3Other · — · PlannedGBushehr-4: Other, plannedBushehr-4Other · — · PlannedGGrid
  • Operating · 1
  • Under construction · 1
  • Planned · 2
  • On this page
Operating
1 unit · 915 MWe netPublished net capacities, from the unit table
Being built or planned
3 units · 974 MWe net
Heat at design rating
about 3,000 MWt in, about 2,100 MWt rejectedDerived: 1 operating unit of a named design, each at its design’s published rating
Plant concepts here
VVER-1000 (2) · Other (2)