Lead-cooled fast reactor.
The lead-cooled fast reactor reference plant concept in 3D. Open a site from the globe, or from the list beside the view, to see its real numbers next to it.
REFERENCE CONCEPT · NOT A SIMULATIONThe lead-cooled fast reactor reference plant.
The family’s reference concept, not any one station. The model illustrates a lead-cooled fast reactor concept, with the generic layout every design in the plant library shares: the reactor island, a turbine hall, air-cooled condensers and a grid connection. It does not show a real station's buildings, number of units, cooling or equipment.
The concept is the family’s generic pool-type reference, a steel vessel with the steam generators and pumps in the lead, not BREST-OD-300’s layout. BREST-OD-300 encloses its lead in a multilayer metal-and-concrete vessel about 26 m across, with the core in a central cavity and the steam generators and pumps in four peripheral cavities.
Molten lead carries heat from a compact fast-neutron core into a pool that fills one large vessel at about atmospheric pressure. Pumps drive the lead through steam generators that sit in the same pool, so water is turned to steam inside the reactor vessel with no intermediate loop.
- Fuel
- Fast-reactor fuel assemblies (nitride or oxide)
- Reaction
- Splitting heavy nuclei
- Energy transfer
- Primary lead pool to in-vessel steam generators
Lead-cooled fast reactor
Molten lead cools a fast-neutron core. It boils at 1,749 °C, so the coolant never needs to be pressurized.