China · Pressurized water reactor

Tianwan.

2 PWR units at Tianwan, beside the pressurized water reference plant concept. The 3D model shows how the family works; it is not Tianwan's actual layout.

Back to the globe at Tianwan
Close view of the illustrative pressurized-water plant concept inside an open steel building frame: the reactor vessel with its control-rod drives, a tall steam generator beside it and coolant piping between them, with the turbine casing at the right edge.REFERENCE CONCEPT · NOT A SIMULATION

Reference still · interactive view loads when available

Reference concept · OPEN100 · PWR

The pressurized water reference plant.

The family’s reference concept, not Tianwan. The model illustrates a pressurized water reactor concept, with the generic layout every design in the plant library shares: the reactor island, a turbine hall, air-cooled condensers and a grid connection. It does not show Tianwan's buildings, number of units, cooling or equipment.

Commercial pressurized water reactors run several coolant loops, typically two to four, and the VVER-440 six, each with its own steam generator and pump; the concept shows one. Units of the VVER, AP1000, EPR, HPR1000 and APR1400 designs open their own concepts, drawn with their real loop counts.

Fission heats water inside the pressure vessel. The primary water stays liquid under pressure and transfers its heat to a separate steam circuit.

Fuel
Uranium dioxide
Reaction
Splitting heavy nuclei
Energy transfer
Pressurized-water primary loop

The OPEN100 reference is rated at 100 MWe. Plant placement, piping, and reconstructed internals are illustrative.

Concept source: OPEN100 reference. Procedural geometry drawn for teaching: source anchors are identified in the component records; other dimensions and placement are illustrative. No physics results are computed.

Spotter’s guide · PWR

Pressurized water reactor

Water held at around 155 bar stays liquid as it carries heat from the core to steam generators, where a second loop boils. The most common reactor on Earth.

VVER · AP1000 · EPR · APR-1400 · Hualong One

The whole station · Tianwan

Tianwan as one power plant.

Every unit on the site, from the atlas’s unit records: each reactor drives its own generator, which feeds the station’s switchyard and the grid. This is a schematic of how the units connect, not the station’s layout; the atlas records no buildings, cooling, switchyard arrangement or grid voltage.

Tianwan-1: VVER-1000, operating, 990 MWe net, 3,000 MWt at design ratingTianwan-1VVER-10003,000 MWtG990 MWeTianwan-2: VVER-1000, operating, 990 MWe net, 3,000 MWt at design ratingTianwan-2VVER-10003,000 MWtG990 MWeTianwan-3: VVER-1000, operating, 1,060 MWe net, 3,000 MWt at design ratingTianwan-3VVER-10003,000 MWtG1,060 MWeTianwan-4: VVER-1000, operating, 1,060 MWe net, 3,000 MWt at design ratingTianwan-4VVER-10003,000 MWtG1,060 MWeTianwan-5: PWR, operating, 1,000 MWe netTianwan-5PWRG1,000 MWeTianwan-6: PWR, operating, 1,000 MWe netTianwan-6PWRG1,000 MWeTianwan-7: VVER-1200, operating, 1,171 MWe net, 3,200 MWt at design ratingTianwan-7VVER-12003,200 MWtG1,171 MWeTianwan-8: VVER-1200, under construction, 1,171 MWe net, 3,200 MWt at design ratingTianwan-8VVER-12003,200 MWtG1,171 MWeBuildingSwitchyardGridTianwan-1: VVER-1000, operating, 990 MWe net, 3,000 MWt at design ratingTianwan-1VVER-1000 · 990 MWeGTianwan-2: VVER-1000, operating, 990 MWe net, 3,000 MWt at design ratingTianwan-2VVER-1000 · 990 MWeGTianwan-3: VVER-1000, operating, 1,060 MWe net, 3,000 MWt at design ratingTianwan-3VVER-1000 · 1,060 MWeGTianwan-4: VVER-1000, operating, 1,060 MWe net, 3,000 MWt at design ratingTianwan-4VVER-1000 · 1,060 MWeGTianwan-5: PWR, operating, 1,000 MWe netTianwan-5PWR · 1,000 MWeGTianwan-6: PWR, operating, 1,000 MWe netTianwan-6PWR · 1,000 MWeGTianwan-7: VVER-1200, operating, 1,171 MWe net, 3,200 MWt at design ratingTianwan-7VVER-1200 · 1,171 MWeGTianwan-8: VVER-1200, under construction, 1,171 MWe net, 3,200 MWt at design ratingTianwan-8VVER-1200 · 1,171 MWe · Build…GGrid
  • Operating · 7
  • Under construction · 1
  • On this page
Operating
7 units · 7,271 MWe netPublished net capacities, from the unit table
Being built or planned
1 unit · 1,171 MWe net
Heat at design rating
about 15,200 MWt in, about 10,430 MWt rejectedDerived: 5 operating units of a named design, each at its design’s published rating; 2 more operating units have no design figures in the library
Plant concepts here
VVER-1000 (4) · VVER-1200 (2) · PWR reference (2)