United Kingdom · Advanced gas-cooled reactor

Dungeness.

2 AGR units at Dungeness, beside the advanced gas-cooled reactor reference plant concept. The 3D model shows how the family works; it is not Dungeness's actual layout.

Back to the globe at Dungeness
Close view of the illustrative advanced gas-cooled reactor concept: a massive concrete cylinder ringed with tendon bands, cut open at the front to show the graphite core and coiled boilers inside it, with gas circulators around its base, a tall fueling machine on top and steam and feed lines on its side, inside an open steel building frame.REFERENCE CONCEPT · NOT A SIMULATION

Reference still · interactive view loads when available

Reference concept · Concept study · AGR

The advanced gas-cooled reactor reference plant.

The family’s reference concept, not Dungeness. The model illustrates a advanced gas-cooled reactor concept, with the generic layout every design in the plant library shares: the reactor island, a turbine hall, air-cooled condensers and a grid connection. It does not show Dungeness's buildings, number of units, cooling or equipment.

Each commercial AGR station has two reactors, and the concept shows one. The stations differ in how their boilers are arranged inside the vessel, and the regulator names graphite ageing, the weight loss and cracking of the core bricks, as the main issue for the cores.

Gas circulators at the bottom of the boilers drive high-pressure carbon dioxide up through fuel channels in a graphite core, where it reaches about 650 °C. The hot gas then passes through boiler units that sit inside the prestressed concrete pressure vessel around the core, raising superheated high-pressure steam that leaves through the vessel wall for the turbine.

Fuel
Enriched uranium dioxide in stainless-steel cladding
Reaction
Splitting heavy nuclei
Energy transfer
Carbon dioxide gas to boilers inside the concrete vessel

The concrete vessel and its tendons, the boilers inside it, the circulators at their base and on-load refueling follow published descriptions. The vessel is scaled down to fit the shared building, and its dimensions, tendon layout, boiler-unit count and pipe routing are illustrative.

Concept source: EDF · Nuclear reactor lifetime management. Procedural geometry drawn for teaching: source anchors are identified in the component records; other dimensions and placement are illustrative. No physics results are computed.

Spotter’s guide · AGR

Advanced gas-cooled reactor

Britain's second generation: still CO2 and graphite, but enriched oxide fuel at higher temperature for better efficiency.

AGR

The whole station · Dungeness

Dungeness as one power plant.

Every unit on the site, from the atlas’s unit records: each reactor drives its own generator, which feeds the station’s switchyard and the grid. This is a schematic of how the units connect, not the station’s layout; the atlas records no buildings, cooling, switchyard arrangement or grid voltage.

Dungeness-A1: GCR, shut down, 275 MWe netDungeness-A1GCRG275 MWeShut downDungeness-A2: GCR, shut down, 275 MWe netDungeness-A2GCRG275 MWeShut downDungeness-B1: AGR, shut down, 607 MWe netDungeness-B1AGRG607 MWeShut downDungeness-B2: AGR, shut down, 607 MWe netDungeness-B2AGRG607 MWeShut downSwitchyardGridDungeness-A1: GCR, shut down, 275 MWe netDungeness-A1GCR · 275 MWe · Shut downGDungeness-A2: GCR, shut down, 275 MWe netDungeness-A2GCR · 275 MWe · Shut downGDungeness-B1: AGR, shut down, 607 MWe netDungeness-B1AGR · 607 MWe · Shut downGDungeness-B2: AGR, shut down, 607 MWe netDungeness-B2AGR · 607 MWe · Shut downGGrid
  • Shut down · 4
  • On this page
Operating
None
Shut down
4 units · 1,764 MWe net
Plant concepts here
GCR reference (2) · AGR reference (2)