Finland · Boiling water reactor

Olkiluoto.

2 BWR units at Olkiluoto, beside the boiling water reference plant concept. The 3D model shows how the family works; it is not Olkiluoto's actual layout.

Back to the globe at Olkiluoto
Close view of the illustrative boiling-water plant concept: one tall reactor vessel rising almost to the crane bridge of its open building frame, with steam and recirculation piping at its base and the turbine casing at the right edge.REFERENCE CONCEPT · NOT A SIMULATION

Reference still · interactive view loads when available

Reference concept · Reference · BWR/4

The boiling water reference plant.

The family’s reference concept, not Olkiluoto. The model illustrates a boiling water reactor concept, with the generic layout every design in the plant library shares: the reactor island, a turbine hall, air-cooled condensers and a grid connection. It does not show Olkiluoto's buildings, number of units, cooling or equipment.

The concept has external recirculation loops, as on earlier boiling water reactor generations. Advanced boiling water reactors (ABWR) move the recirculation pumps inside the vessel, and their units open the ABWR concept.

Fission boils water directly inside the reactor vessel. Separators and a dryer above the core remove droplets before steam leaves for the turbine, so this cycle has no steam generator.

Fuel
Uranium dioxide
Reaction
Splitting heavy nuclei
Energy transfer
Direct cycle: water boils in the vessel

The vessel envelope and main-steam arrangement follow published descriptions; internals spacing, recirculation loops, pedestal, and plant placement are illustrative.

Concept source: US NRC · Boiling water reactors. Procedural geometry drawn for teaching: source anchors are identified in the component records; other dimensions and placement are illustrative. No physics results are computed.

Spotter’s guide · BWR

Boiling water reactor

Water boils inside the reactor vessel and the steam goes straight to the turbine. One loop, no steam generators.

ABWR · ESBWR · BWRX-300

The whole station · Olkiluoto

Olkiluoto as one power plant.

Every unit on the site, from the atlas’s unit records: each reactor drives its own generator, which feeds the station’s switchyard and the grid. This is a schematic of how the units connect, not the station’s layout; the atlas records no buildings, cooling, switchyard arrangement or grid voltage.

Olkiluoto-1: BWR, operating, 660 MWe netOlkiluoto-1BWRG660 MWeOlkiluoto-2: BWR, operating, 660 MWe netOlkiluoto-2BWRG660 MWeOlkiluoto-3: EPR, operating, 1,600 MWe net, 4,590 MWt at design ratingOlkiluoto-3EPR4,590 MWtG1,600 MWeOlkiluoto-4: Other, plannedOlkiluoto-4OtherG—PlannedSwitchyardGridOlkiluoto-1: BWR, operating, 660 MWe netOlkiluoto-1BWR · 660 MWeGOlkiluoto-2: BWR, operating, 660 MWe netOlkiluoto-2BWR · 660 MWeGOlkiluoto-3: EPR, operating, 1,600 MWe net, 4,590 MWt at design ratingOlkiluoto-3EPR · 1,600 MWeGOlkiluoto-4: Other, plannedOlkiluoto-4Other · — · PlannedGGrid
  • Operating · 3
  • Planned · 1
  • On this page
Operating
3 units · 2,920 MWe netPublished net capacities, from the unit table
Being built or planned
1 unit · 0 MWe net
Heat at design rating
4,590 MWt in, 2,820 MWt rejectedDerived: 1 operating unit of a named design, each at its design’s published rating; 2 more operating units have no design figures in the library
Plant concepts here
BWR reference (2) · EPR (1) · Other (1)