United Kingdom · Gas-cooled reactor

Hinkley Point.

2 GCR units at Hinkley Point, beside the gas-cooled graphite reactor reference plant concept. The 3D model shows how the family works; it is not Hinkley Point's actual layout.

Back to the globe at Hinkley Point
Close view of the illustrative gas-cooled graphite reactor concept: a round steel pressure vessel cut open to show its graphite core, with a charge machine on the concrete pile cap above, fat hot-gas ducts running to three tall separate boilers and blowers returning cooled gas to the vessel, inside an open steel building frame.REFERENCE CONCEPT · NOT A SIMULATION

Reference still · interactive view loads when available

Reference concept · Concept study · Magnox

The gas-cooled graphite reactor reference plant.

The family’s reference concept, not Hinkley Point. The model illustrates a gas-cooled reactor concept, with the generic layout every design in the plant library shares: the reactor island, a turbine hall, air-cooled condensers and a grid connection. It does not show Hinkley Point's buildings, number of units, cooling or equipment.

The concept follows the early UK stations, with a steel vessel and the boilers outside it. The later Magnox stations at Oldbury and Wylfa, and most French UNGG reactors, used prestressed concrete vessels instead, some with the boilers inside, and the UK stations mostly ran two reactors where the concept shows one.

Carbon dioxide blown up through vertical channels in a graphite core carries heat away from natural-uranium metal fuel and leaves the steel pressure vessel at about 360 °C. Large ducts take the hot gas to separate tall boilers, where it raises steam, and gas circulators blow the cooled gas back into the bottom of the vessel.

Fuel
Natural uranium metal in magnesium-alloy cans
Reaction
Splitting heavy nuclei
Energy transfer
Carbon dioxide gas to separate boilers

The arrangement follows the early steel-vessel stations: a steel vessel inside a concrete shield, with the boilers, circulators and gas ducts outside it, and a charge machine on the pile cap that refuels while the reactor runs. The plant is scaled down to fit the shared building and shows three of one reactor’s boilers; every dimension, count and route is illustrative.

Concept source: IET · Nuclear reactor types factfile. Procedural geometry drawn for teaching: source anchors are identified in the component records; other dimensions and placement are illustrative. No physics results are computed.

Spotter’s guide · GCR

Gas-cooled reactor

Carbon dioxide cools natural-uranium metal fuel in a graphite core. The first generation of British and French power stations, now all retired.

Magnox · UNGG

The whole station · Hinkley Point

Hinkley Point as one power plant.

Every unit on the site, from the atlas’s unit records: each reactor drives its own generator, which feeds the station’s switchyard and the grid. This is a schematic of how the units connect, not the station’s layout; the atlas records no buildings, cooling, switchyard arrangement or grid voltage.

Hinkley Point-A1: GCR, shut down, 250 MWe netA1GCRG250 MWeShut downHinkley Point-A2: GCR, shut down, 250 MWe netA2GCRG250 MWeShut downHinkley Point-B1: AGR, shut down, 625 MWe netB1AGRG625 MWeShut downHinkley Point-B2: AGR, shut down, 625 MWe netB2AGRG625 MWeShut downHinkley Point-C1: EPR, under construction, 1,630 MWe net, 4,590 MWt at design ratingC1EPR4,590 MWtG1,630 MWeBuildingHinkley Point-C2: EPR, under construction, 1,630 MWe net, 4,590 MWt at design ratingC2EPR4,590 MWtG1,630 MWeBuildingSwitchyardGridHinkley Point-A1: GCR, shut down, 250 MWe netHinkley Point-A1GCR · 250 MWe · Shut downGHinkley Point-A2: GCR, shut down, 250 MWe netHinkley Point-A2GCR · 250 MWe · Shut downGHinkley Point-B1: AGR, shut down, 625 MWe netHinkley Point-B1AGR · 625 MWe · Shut downGHinkley Point-B2: AGR, shut down, 625 MWe netHinkley Point-B2AGR · 625 MWe · Shut downGHinkley Point-C1: EPR, under construction, 1,630 MWe net, 4,590 MWt at design ratingHinkley Point-C1EPR · 1,630 MWe · BuildingGHinkley Point-C2: EPR, under construction, 1,630 MWe net, 4,590 MWt at design ratingHinkley Point-C2EPR · 1,630 MWe · BuildingGGrid
  • Under construction · 2
  • Shut down · 4
  • On this page
Operating
None
Being built or planned
2 units · 3,260 MWe net
Shut down
4 units · 1,750 MWe net
Plant concepts here
EPR (2) · GCR reference (2) · AGR reference (2)