← Three-scale reference explorer

HTR-PM reference-analysis workbench / phase 02

Account for the heat.

Read the published inputs, follow the arithmetic, and explore a hypothetical change. Every result retains its evidence and assumptions.

Steady-state estimate · not a reactor simulation. The display geometry is independent of these calculations.

Published-input audit / model 1.0.0

2016 demonstration design

Primary concept identity. Helium flow and feedwater values are deliberately unpopulated in this transcription; S2 is not silently substituted.

Published module power
250 MW
Source value · not a calculated rating
Required helium flow
96.281 kg/s
Derived from power and temperatures · ideal gas
Carried heat at source flow
Not evaluated
Flow is unpopulated for this source case

The enthalpy model gives a mean heat capacity of 5.19313 kJ/(kg K) across the published 500 K rise. Without a flow value in this case, the carried-heat comparison stays empty. Property source · S5

Inspect every calculated quantity
Unpopulated source inputs remain unpopulated. Inventory averages always use the published rating.
QuantityValueUnitEvidence
Heat carried at published temperatures and flowNot populatedMW/modulederived ideal-gas estimateS1; S5
Carried heat minus published powerNot populatedMW/modulederived difference; not a safety marginS1; S5
Difference relative to published powerNot populated%derived difference; not uncertaintyS1; S5
Flow required for published power and temperatures96.28106kg/s/modulederived, not a published flowS1; S5
Helium enthalpy rise2,596.564685kJ/kgideal-gas property relationS5
Mean model heat capacity5.193129kJ/(kg K)derived from enthalpy riseS5
Heat capacity required for exact table closureNot populatedkJ/(kg K)inferred from published power, temperatures and flowS1
Two-module thermal rating500MWderived sum of published ratingsS1
Electrical / thermal rating ratio0.42fractionrating ratio; not a modeled net efficiencyS1
Required secondary enthalpy gain at full heat transferNot populatedkJ/kgheat-balance demand; not steam-property outputS1
Hot-end helium minus steam temperature183Kdifference of published endpoints; not local pinchS1
Cold-end helium minus feedwater temperatureNot populatedKdifference of published endpoints; not local pinchS1
Equivalent cylindrical core volume77.754418m³derived from mean height and diameterS1; S2
Aggregate sphere volume47.500881m³approximate inventory × sphere volumeS1; S2; S3
Aggregate solid volume fraction0.610909fractiongeometric ratio; not discrete packingS1; S2; S3
Aggregate void volume fraction0.389091fractiongeometric ratio; not local porosityS1; S2; S3
Mean volumetric power at published rating3.215251MW/m³average; no spatial distributionS1
Mean heat per pebble at published rating595.238095W/pebbleaverage; not maximum or fuel temperatureS1
Fuel-bearing zone / pebble volume0.578704fractiongeometric ratio; not fuel material fractionS3
Fuel-free graphite shell thickness0.005mhalf the difference in diametersS3

Keep this calculation

The URL preserves the inputs. Downloads include the source locators, assumptions and model fingerprints.

Reproduce this result

Download the JSON receipt, then run from the matching repository revision with Node 22.18 or later:

npm run htgr:analysis -- --replay receipt.json --out /tmp/htr-pm-replay

The runner checks fingerprints and recomputes all results. The input link uses the current model revision; a saved JSON receipt identifies the exact revision of the calculation files.

algorithm
sha256
definition
3379679e3204ac07b0b68b94de7cc489725c8621395091bd7821f3c65004a24e
model
c5ff39b7d16b0d305fcf04426dd3f682e9db09719d0244570c080792771ae726
state
4263cc664eff25ce1b56c87450ee1dd35f886f892531ff88290d3f8af91b4dc2
presentation
88eadebb31f1a758c097e1e69cac82a6e5c005999ed6465d07bfdaa25fc81099
sourcePacket
6d0deba49c8a20418705b2cbc2e92c2c00ac4eaa8b0de003d9752c9ff21cdab7

Change an assumption

Explore a hypothetical module

Start from the 2017 table’s power, flow and inlet temperature. The outlet is solved from energy conservation; it is not set to the published outlet or used to change the 3D model.

25–300 MW · software bounds
20–140 kg/s · software bounds
50–400 °C · software bounds
Reset scenario inputs

These are software exploration bounds, not licensed operating limits. All applied heat enters one perfectly mixed helium stream. No heat storage, bypass, leakage, blower work or external loss. These native forms and all result tables work without JavaScript or 3D.

Two sources, kept separate

Both describe the same two-module concept, but their steam conditions differ. Neither row is averaged or silently used to fill the other. “Not populated” means not adopted in this workbench’s transcription.

Locked reference inputs · no live plant data
Quantity2016 demonstration designS1 · Section 2, Figure 2, Table 1; abstract2017 system-study basisS2 · Section 2, Table 1Unit
Thermal power per module250250MW
Reactor modules22count
Helium inlet250250°C
Helium outlet750750°C
Helium flow per moduleNot populated96kg/s
Helium pressure77MPa
Steam outlet567571°C
Steam pressure13.2513.9MPa
Feedwater inletNot populated205°C
Feedwater per moduleNot populated98kg/s
Shared electrical rating210Not populatedMW

The steam-generator endpoint differences and required secondary enthalpy rise are bookkeeping only. No water/steam property model, boiling-zone profile or exchanger sizing is calculated.

Check the bed’s aggregate inventory

Equivalent cylinder using mean height, not the actual tapered bed. Uniform non-overlapping spheres; counts and mean height are approximate. Computed void fraction is an aggregate ratio, not a packing solution. This joins core data from S1 / S2 with the sphere dimensions in S3.

Equivalent core volume
77.75 m³
Ø 3 m × 11 m mean height
Aggregate void fraction
38.91%
Approximate 420,000 × Ø 60 mm spheres
Mean heat per pebble
595.2 W
Published 250 MW/module · average, not maximum

These numbers do not count the enlarged markers in the model. The fuel-bearing zone is 57.87% of the pebble’s volume; that is not its uranium fraction.

The complete calculation

The property relation uses Celsius inputs converted to kelvin. Enthalpy differences cancel the arbitrary reference offset. Outlet temperature is found by 64 bounded bisection steps. The numerical residual measures only that arithmetic.

enthalpy

t = (T°C + 273.15) / 1000; h(T) = [A t + B t²/2 + C t³/3 + D t⁴/4 − E/t + F − H] / M

h in kJ/kg; M in kg/mol; coefficients return kJ/mol. [S5]

balance

QHe = ṁ × [h(Tout) − h(Tin)] / 1000; residual = QHe − Qpublished

Q in MW; ṁ in kg/s. [S1] [S2] [S5]

inverse

ṁrequired = 1000 Qpublished / Δh; h(Tout,scenario) = h(Tin) + 1000 Qscenario / ṁscenario

ṁ in kg/s; Tout by bounded bisection. [S5]

inventory

Vcore = π D² H / 4; Vpebble = π d³ / 6; solid fraction = N Vpebble / Vcore; void fraction = 1 − solid fraction

Lengths in metres; volumes in m³; fractions dimensionless. [S1] [S2] [S3]

averages

q̄core = Qpublished / Vcore; P̄pebble = 10⁶ Qpublished / N; fuel-zone volume fraction = (dfuel / dpebble)³

MW/m³; W/pebble; dimensionless fraction. [S1] [S2] [S3]

The published helium pressure is a source annotation. The implemented standard-state relation does not depend on pressure; the pressure-dependent property model in S6 is a candidate for later work.

What this phase establishes

Traceable arithmetic and repeatable inputs, with no fit to force agreement. The following limits remain part of every exported result:

  • Steady-state bookkeeping, not a reactor simulation or a prediction of operating behavior.
  • Standard-state ideal-gas helium enthalpy; pressure effects at the published 7 MPa are not evaluated. No quantified model uncertainty is supplied.
  • All applied heat enters one mixed helium stream. Bypass flow, spatial power shape, losses, heat storage, circulator work and pressure drop are omitted.
  • No water/steam equation of state is implemented. Secondary enthalpy demand and endpoint temperature differences are algebraic annotations, not exchanger sizing or steam-performance predictions.
  • Inventory uses an equivalent cylinder and approximate sphere count. Average heat per pebble is not a peak, particle temperature, packing result or fuel-performance limit.
  • Sensitivity curves vary one input at a time within software bounds. They are neither uncertainty intervals nor safe operating envelopes.
  • Display geometry is independent of these inputs and remains illustrative; no numerical field is painted onto the 3D model.
  • No neutronics, reactivity, transient, decay-heat, accident, safety, licensing or manufacturing conclusion follows from these calculations.

Source register

Public references identify evidence, not a partnership or endorsement. S6 is evaluated for future work and is not used in the calculation.

S1 · Zhang et al. (2016) · HTR-PM demonstration power plant

Primary design-team paper; selected reference basis · Section 2, Figure 2, Table 1; steam-generator subsection

Two 250 MWth modules, one 210 MWe turbine; core 3 m diameter / 11 m height; helium 7 MPa and 250/750 °C; 60 mm pebbles; 420,000 pebbles per core; 19 helical tube assemblies per steam generator.

Historical design basis, not current operation or dimensional manufacturing drawings. HTML read; PDF redirect failed. Accessed 2026-11-07.

S2 · Wang, Shi & Zheng (2017) · HTR-PM steam-generator study

Primary INET system-analysis paper; topology evidence · Section 2, Figures 1–2, Table 1

Table 1: 250 MWth per module, 96 kg/s helium at 250/750 °C, 7 MPa; 98 kg/s feedwater at 205 °C; steam 13.9 MPa and 571 °C. Section 2: 3 m core diameter, 11 m mean bed height and about 420,000 spheres.

A separate 2017 study basis, not a correction to S1. Only steady-state reference values are used; no precooling or accident results are reproduced. Accessed 2026-11-07.

S3 · Yang, Liu & Tang (2014) · HTR-PM fuel element

Primary fuel study; pebble structure evidence · HTR2014-31281, page 1, abstract and introduction

60 mm sphere; 50 mm fuel zone; 5 mm fuel-free graphite shell; approximately 12,000 coated particles. Coatings: buffer carbon, inner pyrocarbon, silicon carbide, outer pyrocarbon.

Particle positions in this concept are authored; no temperature/stress or failure-probability results are reproduced. Accessed 2026-11-06.

S5 · NIST Chemistry WebBook, SRD 69 · Helium

Primary federal reference-data compilation · Gas Phase Heat Capacity (Shomate Equation), 298–6000 K; molecular weight

Molar mass and Shomate coefficients for standard-state gas enthalpy. Mass-specific enthalpy follows unit conversion.

Used as an ideal-gas approximation. No density or pressure-dependent departure function; no uncertainty bound for 7 MPa helium. Data attributed to Chase (1998), reviewed March 1982. Accessed 2026-11-07.

S6 · Ortiz Vega et al. (2023) · NIST IR 8474, helium equation of state

Primary property-model report; evaluated for a later phase · Abstract; DOI 10.6028/NIST.IR.8474

Identifies a pressure-dependent Helmholtz-energy formulation for future real-fluid work.

Abstract read. Equation and REFPROP implementation are not used here. No claim of agreement with that model. Accessed 2026-11-07.