enthalpy
t = (T°C + 273.15) / 1000; h(T) = [A t + B t²/2 + C t³/3 + D t⁴/4 − E/t + F − H] / M
h in kJ/kg; M in kg/mol; coefficients return kJ/mol. [S5]
HTR-PM reference-analysis workbench / phase 02
Read the published inputs, follow the arithmetic, and explore a hypothetical change. Every result retains its evidence and assumptions.
Steady-state estimate · not a reactor simulation. The display geometry is independent of these calculations.
Published-input audit / model 1.0.0
Separate published case. Steam conditions differ from S1. No electrical rating is borrowed from S1.
The enthalpy model gives a mean heat capacity of 5.19313 kJ/(kg K) across the published 500 K rise. The residual is shown rather than removed by fitting the heat capacity. Source rounding and omitted physics are unresolved; the difference is not an accuracy estimate. Property source · S5
| Quantity | Value | Unit | Evidence |
|---|---|---|---|
| Heat carried at published temperatures and flow | 249.27021 | MW/module | derived ideal-gas estimateS2; S5 |
| Carried heat minus published power | -0.72979 | MW/module | derived difference; not a safety marginS2; S5 |
| Difference relative to published power | -0.291916 | % | derived difference; not uncertaintyS2; S5 |
| Flow required for published power and temperatures | 96.28106 | kg/s/module | derived, not a published flowS2; S5 |
| Helium enthalpy rise | 2,596.564685 | kJ/kg | ideal-gas property relationS5 |
| Mean model heat capacity | 5.193129 | kJ/(kg K) | derived from enthalpy riseS5 |
| Heat capacity required for exact table closure | 5.208333 | kJ/(kg K) | inferred from published power, temperatures and flowS2 |
| Two-module thermal rating | 500 | MW | derived sum of published ratingsS2 |
| Electrical / thermal rating ratio | Not populated | fraction | rating ratio; not a modeled net efficiencyS2 |
| Required secondary enthalpy gain at full heat transfer | 2,551.020408 | kJ/kg | heat-balance demand; not steam-property outputS2 |
| Hot-end helium minus steam temperature | 179 | K | difference of published endpoints; not local pinchS2 |
| Cold-end helium minus feedwater temperature | 45 | K | difference of published endpoints; not local pinchS2 |
| Equivalent cylindrical core volume | 77.754418 | m³ | derived from mean height and diameterS1; S2 |
| Aggregate sphere volume | 47.500881 | m³ | approximate inventory × sphere volumeS1; S2; S3 |
| Aggregate solid volume fraction | 0.610909 | fraction | geometric ratio; not discrete packingS1; S2; S3 |
| Aggregate void volume fraction | 0.389091 | fraction | geometric ratio; not local porosityS1; S2; S3 |
| Mean volumetric power at published rating | 3.215251 | MW/m³ | average; no spatial distributionS2 |
| Mean heat per pebble at published rating | 595.238095 | W/pebble | average; not maximum or fuel temperatureS2 |
| Fuel-bearing zone / pebble volume | 0.578704 | fraction | geometric ratio; not fuel material fractionS3 |
| Fuel-free graphite shell thickness | 0.005 | m | half the difference in diametersS3 |
The URL preserves the inputs. Downloads include the source locators, assumptions and model fingerprints.
Download the JSON receipt, then run from the matching repository revision with Node 22.18 or later:
npm run htgr:analysis -- --replay receipt.json --out /tmp/htr-pm-replayThe runner checks fingerprints and recomputes all results. The input link uses the current model revision; a saved JSON receipt identifies the exact revision of the calculation files.
sha2563379679e3204ac07b0b68b94de7cc489725c8621395091bd7821f3c65004a24ec5ff39b7d16b0d305fcf04426dd3f682e9db09719d0244570c080792771ae7264263cc664eff25ce1b56c87450ee1dd35f886f892531ff88290d3f8af91b4dc288eadebb31f1a758c097e1e69cac82a6e5c005999ed6465d07bfdaa25fc810996d0deba49c8a20418705b2cbc2e92c2c00ac4eaa8b0de003d9752c9ff21cdab7Change an assumption
Start from the 2017 table’s power, flow and inlet temperature. The outlet is solved from energy conservation; it is not set to the published outlet or used to change the 3D model.
Both describe the same two-module concept, but their steam conditions differ. Neither row is averaged or silently used to fill the other. “Not populated” means not adopted in this workbench’s transcription.
| Quantity | 2016 demonstration designS1 · Section 2, Figure 2, Table 1; abstract | 2017 system-study basisS2 · Section 2, Table 1 | Unit |
|---|---|---|---|
| Thermal power per module | 250 | 250 | MW |
| Reactor modules | 2 | 2 | count |
| Helium inlet | 250 | 250 | °C |
| Helium outlet | 750 | 750 | °C |
| Helium flow per module | Not populated | 96 | kg/s |
| Helium pressure | 7 | 7 | MPa |
| Steam outlet | 567 | 571 | °C |
| Steam pressure | 13.25 | 13.9 | MPa |
| Feedwater inlet | Not populated | 205 | °C |
| Feedwater per module | Not populated | 98 | kg/s |
| Shared electrical rating | 210 | Not populated | MW |
The steam-generator endpoint differences and required secondary enthalpy rise are bookkeeping only. No water/steam property model, boiling-zone profile or exchanger sizing is calculated.
Equivalent cylinder using mean height, not the actual tapered bed. Uniform non-overlapping spheres; counts and mean height are approximate. Computed void fraction is an aggregate ratio, not a packing solution. This joins core data from S1 / S2 with the sphere dimensions in S3.
These numbers do not count the enlarged markers in the model. The fuel-bearing zone is 57.87% of the pebble’s volume; that is not its uranium fraction.
The property relation uses Celsius inputs converted to kelvin. Enthalpy differences cancel the arbitrary reference offset. Outlet temperature is found by 64 bounded bisection steps. The numerical residual measures only that arithmetic.
t = (T°C + 273.15) / 1000; h(T) = [A t + B t²/2 + C t³/3 + D t⁴/4 − E/t + F − H] / M
h in kJ/kg; M in kg/mol; coefficients return kJ/mol. [S5]
QHe = ṁ × [h(Tout) − h(Tin)] / 1000; residual = QHe − Qpublished
ṁrequired = 1000 Qpublished / Δh; h(Tout,scenario) = h(Tin) + 1000 Qscenario / ṁscenario
ṁ in kg/s; Tout by bounded bisection. [S5]
Vcore = π D² H / 4; Vpebble = π d³ / 6; solid fraction = N Vpebble / Vcore; void fraction = 1 − solid fraction
Lengths in metres; volumes in m³; fractions dimensionless. [S1] [S2] [S3]
q̄core = Qpublished / Vcore; P̄pebble = 10⁶ Qpublished / N; fuel-zone volume fraction = (dfuel / dpebble)³
The published helium pressure is a source annotation. The implemented standard-state relation does not depend on pressure; the pressure-dependent property model in S6 is a candidate for later work.
Traceable arithmetic and repeatable inputs, with no fit to force agreement. The following limits remain part of every exported result:
Public references identify evidence, not a partnership or endorsement. S6 is evaluated for future work and is not used in the calculation.
Primary design-team paper; selected reference basis · Section 2, Figure 2, Table 1; steam-generator subsection
Two 250 MWth modules, one 210 MWe turbine; core 3 m diameter / 11 m height; helium 7 MPa and 250/750 °C; 60 mm pebbles; 420,000 pebbles per core; 19 helical tube assemblies per steam generator.
Primary INET system-analysis paper; topology evidence · Section 2, Figures 1–2, Table 1
Table 1: 250 MWth per module, 96 kg/s helium at 250/750 °C, 7 MPa; 98 kg/s feedwater at 205 °C; steam 13.9 MPa and 571 °C. Section 2: 3 m core diameter, 11 m mean bed height and about 420,000 spheres.
Primary fuel study; pebble structure evidence · HTR2014-31281, page 1, abstract and introduction
60 mm sphere; 50 mm fuel zone; 5 mm fuel-free graphite shell; approximately 12,000 coated particles. Coatings: buffer carbon, inner pyrocarbon, silicon carbide, outer pyrocarbon.
Primary federal reference-data compilation · Gas Phase Heat Capacity (Shomate Equation), 298–6000 K; molecular weight
Molar mass and Shomate coefficients for standard-state gas enthalpy. Mass-specific enthalpy follows unit conversion.
Primary property-model report; evaluated for a later phase · Abstract; DOI 10.6028/NIST.IR.8474
Identifies a pressure-dependent Helmholtz-energy formulation for future real-fluid work.