Run and reproduce a lab.
Keep a result another researcher can rerun and check.
0 of 4 checkpoints complete. Continue at step 1 ↓
STEP 1 / 4
Freeze the environment
Select a lab. Download and extract the ZIP. Follow the README to create its environment.
Foundations. An environment is a separate set of programs installed only for this lab.
Explore this research question ↗Read the other explanation levels
Applied. Use the verified Linux dependency lock when available; record any deviation instead of silently mixing versions.
Research. Pin transitive dependencies and retain executable inputs. Numerical libraries, parallel reductions and compiler choices can influence reproducibility.
Checkpoint
Is recording only the solver name enough?
Show explanation
Keep its version, dependency lock, script hash, inputs and operating system. The package provides version pins and a run receipt.
STEP 2 / 4
Predict the reference answer
Read the lab equation and assumptions. Calculate the expected answer before you run anything.
Foundations. A reference answer lets you see when a result is wrong.
Explore this research question ↗Read the other explanation levels
Applied. The absorber predicts exp(−ΣL). Constant diffusion with fixed endpoint concentrations produces a linear steady profile when there is no source.
Research. Use a curved source-driven diffusion solution to measure mesh error. A linear finite-element method can already represent a linear solution exactly, so that alone cannot demonstrate convergence order.
Checkpoint
What does agreement with an analytical solution establish?
Show explanation
It verifies this restricted numerical case. It does not validate a real fusion chamber model.
STEP 3 / 4
Run a controlled refinement
Run the lab command. Compare the errors for both particle counts, or for all three meshes.
Foundations. Change one setting at a time. Then you know what caused the difference.
Explore this research question ↗Read the other explanation levels
Applied. Monte Carlo standard error typically scales as N⁻½. For a smooth problem, piecewise-linear concentration interpolation can show second-order error reduction under mesh refinement.
Research. Separate statistical fluctuations, finite-mesh error, solver tolerances and model-form bias. Check conservation and convergence rather than judging a plot by appearance.
Checkpoint
Does more computation remove every kind of uncertainty?
Show explanation
More histories reduce sampling noise; mesh refinement reduces discretization error. Neither fixes incorrect physics or material data.
STEP 4 / 4
Keep the receipt and limits
Keep results/receipt.json, the lock file and your input changes together. Write down one physical process the lab leaves out.
Foundations. Keep enough information that another person can repeat what you did.
Explore this research question ↗Read the other explanation levels
Applied. The receipt includes solver version, script hash, reference comparison and measured runtime. Installation time is separate.
Research. Treat the successful benchmark as a verified baseline. Add effects incrementally with independent reference checks and an uncertainty budget.
Checkpoint
Can the plant-cycle button replace this solver run?
Show explanation
No. The cycle explains the sequence of physical processes. These downloaded labs run real, deliberately restricted calculations on your computer.