Explore / inspect / follow the energy

A plant you can step into.

HTR-PM · 2016 demonstration design basis. A visual concept with authored hardware, material finishes and a guided fuel-to-grid story.

Plant preview / 03 / Reactor
Generated walkthrough still: two pebble-bed modules, an open turbine hall, generator, cooling bank and grid connection. Layout and hardware detail are illustrative.
NOT A SIMULATION Illustrative walkthrough

From the plant to a single fastener

Step inside the concept.

Explore equipment, inspect surfaces, and follow the energy story.

Procedural geometry · no downloads or account required

The still image and complete text tour are available before loading 3D.

The energy story

Fuel in. Electricity out.

Eight authored chapters · 64 seconds of storytelling, not plant time. Fuel, helium, water and electricity remain distinct.

Playback is off for reduced motion or data saving. Use chapter buttons or the timeline to inspect still states.

Load & recirculate

Markers stand for pebbles entering the bed and returning through a schematic handling loop. Fuel remains in the nuclear island.

Source relationship · S4

What you are looking at

Source relationships.
Authored visual detail.

This is a visual interpretation of one documented pebble-bed arrangement, not the layout of every HTGR or gas-cooled reactor. The two-module relationship, core and fuel-pebble dimensions and separation of the helium and water circuits come from the reference sources.

Buildings, equipment placement, turbine internals, bolts, screws, threads, cooling bank and worn finishes are illustrative. Cutaways remove material for viewing. The isolated fuel specimen is moved outside the vessel. No wear, temperature, reaction rate, operating time or electrical output is calculated here.

Source-backed geometry and citations → · Separate reference calculations →

Accessible tour

Every stop, in words.

The still image, stop links and this explanation work without WebGL or JavaScript.

The whole plant

Two pebble-bed reactor modules deliver heat to two steam generators. One turbine and generator turn that heat into electricity.

Open walls reveal the equipment. Buildings, spacing, service platforms and conventional plant equipment are an authored arrangement, not the station layout.

Plant in metres · layout illustrative

Open this stop · Reference S1
Fuel arrives as pebbles

Graphite fuel pebbles enter from above. An illustrative handling loop traces discharge, inspection and a possible return to the top. This is distinct from the sealed helium circuit.

Hoppers, sorter, transport route and drive hardware are teaching geometry. Actual handling and burnup decisions are not simulated.

Metres · transport route schematic

Open this stop · Reference S4
Inside the pebble bed

Heat is released inside coated fuel particles within graphite pebbles. Helium passes down through the bed and carries heat away. The cutaway lets you look through the vessel and reflector.

The core envelope follows the 3 m diameter and 11 m height reference. The sparse, enlarged bed markers are not an actual packing or particle population.

Core Ø 3 m × 11 m · source dimensions

Open this stop · Reference S1
Follow the helium

Hot helium leaves the lower core through the inner hot duct. After giving up heat in the steam generator, helium returns through the circulator and outer passage, then rises toward the top of the core.

The separated display paths make the coaxial duct and return leg legible. Duct bends, channel offsets and moving markers are illustrative.

Metres · flow markers enlarged

Open this stop · Reference S2
Heat crosses a tube wall

Helium and water remain in separate circuits. Water rises inside the helical tubes; helium releases heat outside them. Steam leaves for the common turbine.

Nineteen representative coil positions echo the documented assembly arrangement. Tube turns, diameters and local supports are authored, not tube-by-tube CAD.

Metres · representative coils

Open this stop · Reference S2
Steam becomes shaft work

Steam expands through the turbine and turns the common shaft. Open the casing to see representative rotor discs and blades.

The turbine blades, casing, fasteners and steam path are authored teaching detail. Rotation rate and blade count are visual choices.

Metres · internals illustrative

Open this stop · Reference S1
The generator

The turbine shaft drives the generator. The exposed rotor and copper-coloured windings show the idea of mechanical-to-electrical conversion.

Windings and rotor are symbolic geometry; this view does not calculate electromagnetic fields, torque or electrical output.

Metres · generator illustrative

Open this stop · Reference S1
Close the steam circuit

Exhaust steam reaches a condenser and returns to liquid. A separate cooling-water circuit carries rejected heat away.

The condenser shell, tube bundle and cooling connection are conventional explanatory equipment, not an as-built condenser design.

Metres · balance of plant inferred

Open this stop · Reference S1
Rejected heat leaves the plant

This authored cooling bank makes the heat-rejection side of the cycle visible. Cooling water returns to the condenser after releasing heat to the surroundings.

The fan-bank choice is a visual placeholder. It does not identify the reference station’s cooling installation or predict water use.

Metres · cooling choice illustrative

Open this stop · Reference S1
Water returns to the heaters

Condensate passes through an illustrative tank and pump set before returning as feedwater to the steam generators. The full visual loop now closes.

The display simplifies heaters, chemistry, valves and auxiliary branches. It is a process story, not a complete piping and instrumentation diagram.

Metres · simplified water circuit

Open this stop · Reference S2
Power leaves the site

The generator feeds a transformer and switchyard. The outgoing conductors complete the visual journey from fuel to useful electrical energy.

Transformer cooling fins, bushings and switchyard are authored. Voltage levels, electrical protections and losses are not modeled.

Metres · electrical equipment illustrative

Open this stop · Reference S1
Down to the fastener

Inspect a representative service-joint fastener: helical thread, hexagonal nut, washer and slotted cover screws. Zoom closely to see machining marks and cosmetic staining.

An authored 36 mm shaft example, not a specified reactor bolt. Wear is a visual art control, not measured corrosion or remaining service life.

Millimetres · assumed 36 mm shaft

Open this stop
One fuel pebble

An isolated 60 mm graphite sphere contains a 50 mm fuel zone. Enlarge the view to see a representative cut face and dispersed coated-particle symbols.

The specimen is moved outside the vessel for inspection. Particle symbols are sampled and enlarged; individual coating layers are not resolved.

Ø 60 mm · fuel zone Ø 50 mm

Open this stop · Reference S3

Complete process story

From fuel to grid.

Shown in chapters for explanation. A plant’s processes overlap; this is not an operating procedure.

  1. Load & recirculate

    Markers stand for pebbles entering the bed and returning through a schematic handling loop. Fuel remains in the nuclear island. [S4]

  2. Release heat

    The bed brightens to represent heat release within the fuel. This is a visual cue, not a temperature field or a neutron calculation. [S1]

  3. Move heat in helium

    Helium carries heat down the bed and along the hot duct, then cools in the steam generator and returns. Moving dots stand for direction only. [S2]

  4. Make steam

    A new set of markers starts on the water side. Heat crosses the tube wall; helium and steam never mix. Steam heads to the shared turbine. [S2]

  5. Turn the shaft

    The shaft and representative rotor discs turn. The visual speed is chosen for legibility, not the machine operating speed. [S1]

  6. Deliver electricity

    The generator feeds the transformer and outgoing conductors. The markers describe the energy chain; they are not electrons traveling from the fuel. [S1]

  7. Reject unused heat

    Turbine exhaust condenses while a separate cooling circuit carries heat to the illustrative fan bank. These circuits are shown as separate equipment paths. [S1]

  8. Return the water

    Water returns through the condensate/feedwater equipment to the steam generators. The sequence stops here; a running plant would maintain continuous overlapping flows. [S2]

Come back to this view.

Bookmark this page, or use “Copy this stop’s link” to return to a particular component. From the website checkout, launch it with npm run reactors -- htgr-walkthrough.